Medium voltage series (200-600V)

Structural Design of Medium Voltage Battery System:
The overall series parallel form of the system is 108 strand 2 and, The voltage range of the battery pack is 324V~459V, The total power consumption is 16. 2kWh, Capacity is 40Ah.
The battery system contains 4 individual 2 and 27 String battery module, Contactor, hall sensor , Pre charging relay, Pre charge resistor, MSD, Cooling fan, etc.
project
Design Results
Series parallel connection method
2and108strand
Voltage range
324V~459V
Rated energy
16. 2kWh
Number of cycles
1000second
size
800*600*260 mm
- Battery system parameters
- Composition of battery system
Single cell performance:
-
project
Single cell battery parameters
Nominal capacity
20Ah
Nominal voltage
3. 75V
Voltage range
3V~4. 25V
energy density
270Wh/kg
cycle life
1000second@80%
size
10. 8*88*188 mm
- Single cell battery parameters
- Outline drawing of individual battery